{"id":1204,"date":"2024-07-25T07:59:25","date_gmt":"2024-07-25T07:59:25","guid":{"rendered":"https:\/\/knowledgewap.org\/blog\/?p=1204"},"modified":"2024-07-25T07:59:25","modified_gmt":"2024-07-25T07:59:25","slug":"implementing-an-nfpa-70b-maintenance-program-steps-and-considerations","status":"publish","type":"post","link":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/","title":{"rendered":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">NFPA 70B is a standard that should not be overlooked. It provides guidelines for electrical system maintenance. The standard gives accurate recommendations concerning the maintenance of electric power systems and components and points out the need for planning to avoid failures in electric systems.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This article gives an insight into the basic concepts and requirements that are crucial in ensuring that the NFPA 70B maintenance program is implemented correctly and effectively, including training, scheduling, automation, analysis, safety, and compliance.<\/span><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#Identify_Training_Needs\" >Identify Training Needs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#Develop_a_Maintenance_Schedule\" >Develop a Maintenance Schedule<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#Utilize_Technology_and_Tools\" >Utilize Technology and Tools<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#Conduct_Root-Cause_Analysis\" >Conduct Root-Cause Analysis<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#Summary\" >Summary<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Identify_Training_Needs\"><\/span><span style=\"font-weight: 400;\">Identify Training Needs<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The training to execute the <\/span><a href=\"https:\/\/facilityresults.com\/nfpa-70b-electrical-maintenance-training\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">NFPA 70B<\/span><\/a><span style=\"font-weight: 400;\"> maintenance program is vital to personnel who service electrical equipment and those who work near electrical equipment. The NFPA 70B Electrical Maintenance Training offers solutions customized according to a particular company\u2019s requirements and technical know-how challenges.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This involves the diagnosis of faults and causes and the practical demonstration of the application of maintenance concepts to the organization&#8217;s equipment and systems. This way, the participants have an opportunity to find any flaws in the electrical system and fix them before they lead to failure.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Develop_a_Maintenance_Schedule\"><\/span><span style=\"font-weight: 400;\">Develop a Maintenance Schedule<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The maintenance schedule is critical when implementing the NFPA 70B maintenance program. The schedule should include the preventive maintenance plan, which covers inspecting, testing, and servicing electrical equipment according to manufacturers\u2019 recommendations and general practices.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">These measures consist of the preventive inspection of electrical <\/span><span style=\"font-weight: 400;\">systems<\/span><span style=\"font-weight: 400;\"> by their physical examination and functionality and the testing of electrical components, including insulation, thermal, and circuit breaker tests. Also, routine maintenance such as cleaning, lubrication, and connection tightening should be scheduled to prevent the equipment&#8217;s wearing and tear.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Utilize_Technology_and_Tools\"><\/span><span style=\"font-weight: 400;\">Utilize Technology and Tools<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Electrical management also requires embracing technology and the right equipment. The tools range from the basic to the advanced. They include infrared and ultrasonic analysis tools, which are used to detect defects that cannot be detected by a simple visual check.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, the maintenance team can identify and rectify all the problems that could lead to failure. Also, an online Arc Flash project management dashboard may be helpful for maintenance. This technology enhances the maintenance schedule since all the tasks are checked and tracked until completion.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conduct_Root-Cause_Analysis\"><\/span><span style=\"font-weight: 400;\">Conduct Root-Cause Analysis<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">When electrical problems occur, they should be solved to avoid the recurrence of the same problem. According to the NFPA 70B maintenance program, the causes of failure and subsequent actions are identified to prevent such failures.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This involves looking at the history of the failed equipment, how it has failed in the past, and determining the root cause of the failure. Therefore, the root cause can be targeted to make the electrical systems more reliable and durable.<\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Summary\"><\/span><span style=\"font-weight: 400;\">Summary<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">For a company to have an effective NFPA 70B maintenance program, it should ensure the safety and reliability of the electrical system in a facility. Therefore, facilities can develop a reliable maintenance program, minimize <\/span><a href=\"https:\/\/www.cnn.com\/2020\/03\/05\/health\/fda-bans-electrical-shock-device\/index.html\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">risks<\/span><\/a><span style=\"font-weight: 400;\">, and enhance work performance by identifying training needs, integrating technology, identifying causes of failures, and ensuring safety compliance. By doing so, organizations can avoid loss, increase the performance of electrical systems, and manage electrical systems.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>NFPA 70B is a standard that should not be overlooked. It provides guidelines for electrical system maintenance. The standard gives accurate recommendations concerning the maintenance of electric power systems and components and points out the need for planning to avoid failures in electric systems.\u00a0 This article gives an insight into the basic concepts and requirements &#8230; <a title=\"Implementing An NFPA 70B Maintenance Program: Steps And Considerations\" class=\"read-more\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\" aria-label=\"Read more about Implementing An NFPA 70B Maintenance Program: Steps And Considerations\">Read more<\/a><\/p>\n","protected":false},"author":9,"featured_media":1205,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[32],"tags":[],"class_list":["post-1204","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tech"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap\" \/>\n<meta property=\"og:description\" content=\"NFPA 70B is a standard that should not be overlooked. It provides guidelines for electrical system maintenance. The standard gives accurate recommendations concerning the maintenance of electric power systems and components and points out the need for planning to avoid failures in electric systems.\u00a0 This article gives an insight into the basic concepts and requirements ... Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\" \/>\n<meta property=\"og:site_name\" content=\"Knowledgewap\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-25T07:59:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"684\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sweety\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sweety\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\"},\"author\":{\"name\":\"sweety\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/da9c6def29430412be80fcfe9f3c8c00\"},\"headline\":\"Implementing An NFPA 70B Maintenance Program: Steps And Considerations\",\"datePublished\":\"2024-07-25T07:59:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\"},\"wordCount\":513,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg\",\"articleSection\":[\"Tech\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\",\"url\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\",\"name\":\"Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap\",\"isPartOf\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg\",\"datePublished\":\"2024-07-25T07:59:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage\",\"url\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg\",\"contentUrl\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg\",\"width\":1024,\"height\":684,\"caption\":\"NFPA 70B Maintenance Program\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/knowledgewap.org\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Implementing An NFPA 70B Maintenance Program: Steps And Considerations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#website\",\"url\":\"https:\/\/knowledgewap.org\/blog\/\",\"name\":\"Knowledgewap\",\"description\":\"Explore a World of Knowledge with Knowledgewap\",\"publisher\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/knowledgewap.org\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#organization\",\"name\":\"Knowledgewap\",\"url\":\"https:\/\/knowledgewap.org\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2023\/11\/knowledgewap-org-logo.png\",\"contentUrl\":\"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2023\/11\/knowledgewap-org-logo.png\",\"width\":263,\"height\":54,\"caption\":\"Knowledgewap\"},\"image\":{\"@id\":\"https:\/\/knowledgewap.org\/blog\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/da9c6def29430412be80fcfe9f3c8c00\",\"name\":\"sweety\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/57181b2f67a2376dae6863f5f068679982485e1511dd4ba64178ec061facda89?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/57181b2f67a2376dae6863f5f068679982485e1511dd4ba64178ec061facda89?s=96&d=mm&r=g\",\"caption\":\"sweety\"},\"url\":\"https:\/\/knowledgewap.org\/blog\/author\/sweety\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/","og_locale":"en_US","og_type":"article","og_title":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap","og_description":"NFPA 70B is a standard that should not be overlooked. It provides guidelines for electrical system maintenance. The standard gives accurate recommendations concerning the maintenance of electric power systems and components and points out the need for planning to avoid failures in electric systems.\u00a0 This article gives an insight into the basic concepts and requirements ... Read more","og_url":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/","og_site_name":"Knowledgewap","article_published_time":"2024-07-25T07:59:25+00:00","og_image":[{"width":1024,"height":684,"url":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg","type":"image\/jpeg"}],"author":"sweety","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sweety","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#article","isPartOf":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/"},"author":{"name":"sweety","@id":"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/da9c6def29430412be80fcfe9f3c8c00"},"headline":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations","datePublished":"2024-07-25T07:59:25+00:00","mainEntityOfPage":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/"},"wordCount":513,"commentCount":0,"publisher":{"@id":"https:\/\/knowledgewap.org\/blog\/#organization"},"image":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage"},"thumbnailUrl":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg","articleSection":["Tech"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/","url":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/","name":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations - Knowledgewap","isPartOf":{"@id":"https:\/\/knowledgewap.org\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage"},"image":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage"},"thumbnailUrl":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg","datePublished":"2024-07-25T07:59:25+00:00","breadcrumb":{"@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#primaryimage","url":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg","contentUrl":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2024\/07\/nfpa70b-safety.jpg","width":1024,"height":684,"caption":"NFPA 70B Maintenance Program"},{"@type":"BreadcrumbList","@id":"https:\/\/knowledgewap.org\/blog\/implementing-an-nfpa-70b-maintenance-program-steps-and-considerations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/knowledgewap.org\/blog\/"},{"@type":"ListItem","position":2,"name":"Implementing An NFPA 70B Maintenance Program: Steps And Considerations"}]},{"@type":"WebSite","@id":"https:\/\/knowledgewap.org\/blog\/#website","url":"https:\/\/knowledgewap.org\/blog\/","name":"Knowledgewap","description":"Explore a World of Knowledge with Knowledgewap","publisher":{"@id":"https:\/\/knowledgewap.org\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/knowledgewap.org\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/knowledgewap.org\/blog\/#organization","name":"Knowledgewap","url":"https:\/\/knowledgewap.org\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/knowledgewap.org\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2023\/11\/knowledgewap-org-logo.png","contentUrl":"https:\/\/knowledgewap.org\/blog\/wp-content\/uploads\/2023\/11\/knowledgewap-org-logo.png","width":263,"height":54,"caption":"Knowledgewap"},"image":{"@id":"https:\/\/knowledgewap.org\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/da9c6def29430412be80fcfe9f3c8c00","name":"sweety","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/knowledgewap.org\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/57181b2f67a2376dae6863f5f068679982485e1511dd4ba64178ec061facda89?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/57181b2f67a2376dae6863f5f068679982485e1511dd4ba64178ec061facda89?s=96&d=mm&r=g","caption":"sweety"},"url":"https:\/\/knowledgewap.org\/blog\/author\/sweety\/"}]}},"_links":{"self":[{"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/posts\/1204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/comments?post=1204"}],"version-history":[{"count":1,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/posts\/1204\/revisions"}],"predecessor-version":[{"id":1206,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/posts\/1204\/revisions\/1206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/media\/1205"}],"wp:attachment":[{"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/media?parent=1204"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/categories?post=1204"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/knowledgewap.org\/blog\/wp-json\/wp\/v2\/tags?post=1204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}